国产一级一级理论片一区二区_久久综合图区亚洲综合图区_国产精品V欧美精品av日韩_日韩精品成人在线_亚洲欧美日韩动漫_国产精品一二三区在线观看公司_日韩成人无码一区二区三区


免費注冊快速求購


分享
舉報 評價

harvard KTR 4壓力控制 動物*

參考價面議
具體成交價以合同協(xié)議為準

該廠商其他產(chǎn)品

我也要出現(xiàn)在這里

harvard儀器公司制造動物*已有75年多的歷史。這些*都基于William T. Porter的創(chuàng)意日漸深入,作為harvard醫(yī)學(xué)院的生理學(xué)教授動力,他強烈支持通過美國生理學(xué)協(xié)會進行生理學(xué)教育和培訓(xùn),他也是harvard儀器公司的創(chuàng)始人互動式宣講。

詳細信息 在線詢價

 

harvard儀器公司制造已有75年多的歷史生產效率。這些*都基于william t. porter的創(chuàng)意,作為harvard醫(yī)學(xué)院的生理學(xué)教授適應性,他強烈支持通過美國生理學(xué)協(xié)會進行生理學(xué)教育和培訓(xùn)節點,他也是harvard儀器公司的創(chuàng)始人。對于從小鼠到大狗的多種物種(15g-50kg)落地生根,有一大批可供選擇的特點。

harvard ktr-4壓力控制*適用于從50克到6/8公斤的大鼠到兔子類動物. 本機提供每分鐘1到199次呼吸和1到99%可調(diào)節(jié)的 i:e 率.

•   嚙齒類動物,zui大到兔子
•   避免過度呼吸的危險以及對肺部的損傷.
•   可變呼吸比,ins/exp ratio
•  “plateau”功能保證了終端呼吸壓力.
 

 
the ktr-4 is used for ventilating the most frequently used animals in the laboratory, from rodent to rabbit. it employs electronic control. this permits flexible adaptation of the ventilation parameters to the most diverse experimental conditions. the functional sequence is signaled by suitably marked signal leds. the ventilation sequence can also be influenced by external signals.

unlike a starling piston pump, use of the ktr-4 avoids the danger of excessively extending and damaging the lung of the ventilated animal through incorrect setting of the stroke volume. the electronic control of the ktr-4 also permits free se-lection of the ventilation timing over a wide range in order to adapt it to the requirements of your experiment. due to the basic design of a starling pump, it is impossible to vary the ratio of inspiration to expiration, for example.

the ktr-4 operates on the principle of intermittent positive pressure ventilation. a continuously adjustable air (gas) stream is passed by solenoid valves either to the animal or to an overflow outlet. the effective pressure in the ventilation cannula is measured and indicated. by suitable settings on the unit it is possible to utilize the measuring circuit to terminate the inspiration process when a given adjustable ventilation pressure has been reached (eip limit: 0–29 cmh20). this effectively protects the animal against excessive pressure rise in the lung.

through the “plateau” function, the end-inspiratory pressure can be maintained constant over an adjustable period of time. this function permits direct control of the inspired air retention. measurements can also be performed in the inspired condition.
the air flow to the ventilated animal is adjusted by means of a built-in needle valve. the set air flow is indicated on a float flowmeter (rotameter).

the connection to the tracheal cannula is made through a specially formed y-shaped ventilation cannula. it carries the following tubing on its three ends: inspiration (4 mm dia.), expiration (6 mm dia.) and pressure measurement (4 mm dia.).
the ventilation air required is normally supplied by a built-in pump. there is also a provision for introducing ventilation gas from outside (max. pressure: 0.5 bar). a special version has the internal pump replaced by a precision pressure regulator; in this case the supply has to be provided by an external pressure source (pressure range: 2 - 8 bar).

adjustable ventilation parameters:
• ventilation rate: 1–199 bpm (breaths per minute), digital setting.
• ratio of inspiration to expiration period: 1–99%, digital setting.
• plateau duration: 0–99% (of total cycle time); measurements can be performed in the inspired condition.
• adjustable continuous air flow: 4 l/min max.
• minute volume range: up to 2000 ml/min (“inspir” = 50%).

pressure measurement and se-lected digital display (range: 29.9 cmh20)
• eip (end-inspiratory pressure).
• eep (end-expiratory pressure).
• limit display of set pressure limit eip limit (0 - 29 cmh20).
• leak al. display of alarm setting for pressure dr-op.

electrical outputs:
• recording output for ventilation pressure: 0.1 v/cmh20
• trigger output (ttl) to synchronize external equipment.

other functions:
• alarm function: audible/visual on pressure dr-op, alarm level adjustable.
• indication of function sequence by leds.

external control facilities (ttl level, active low):
• stop cycle: the cyclic sequence is stopped immediay.
• trigger one cycle (in trig.ext. mode).
• stop after expiration.
• stop after inspiration.
• close expiration valve (in trig.ext. mode).
• open inspiration valve (in trig.ext. mode).

air/gas connections:
• outlet for expiration air/gas (exhaust expir), immersion tube for peep adjustment is connected here, gas is sampled here for analysis of expired gas.
• outlet for unused air or gas (exhaust overflow).
• connections for halothane vaporizer (from/to halothane vaporizer).

the ventilator is delivered with the tracheal cannula adapter (73-2943) and two cannulae with 2.5mm (73-2725) and 3.0mm (73-2724) od. all cannulae with luer connector for tracheotomy or intubation can be connected to this adapter.

for larger animals like rabbits or small cats, special cannulae with 4.0mm (73-2938), 5.0mm (73-2939) or 6.0mm (73-2940) are available.
hidealltabs();showtab("itemlisting");


同類產(chǎn)品推薦


提示

×

*您想獲取產(chǎn)品的資料:

以上可多選共同努力,勾選其他,可自行輸入要求

個人信息:

台中市| 逊克县| 安乡县| 会宁县| 高安市| 会东县| 新营市| 衡南县| 屏东市| 新源县| 临湘市| 新宁县| 黎平县| 仁化县| 曲周县| 颍上县| 云林县| 河曲县| 佛山市| 锡林浩特市| 张家港市| 梁平县| 罗江县| 公安县| 蓬溪县| 五寨县| 衡山县| 汉中市| 克东县| 塘沽区| 柞水县| 峡江县| 建德市| 景德镇市| 峨边| 马尔康县| 永和县| 阆中市| 昭苏县| 衢州市| 尖扎县|